  1. NGS Equipment (item 11)
    • The specific model indicated under the NGS (Next Generation Sequencing) equipment is hereby removed. Bidders may propose any compliant manufacture and model that meets the technical requirements and performance specifications outlined in the tender document.
  2. RT-PCR Platform( item 14,15)
    • The RT-PCR Platform item is hereby removed from the tender and shall no longer form part of this procurement process
  3. Addition of other Laboratory Equipment
    • Other laboratory equipment has been incorporated into the tender document. The detailed technical specifications and requirements for the added equipment are provided in the annexed table below.
  4. Removal of Quantities
  • The quantities specified in the tender document are hereby removed from the tender document and shall no longer form part of this procurement process

Bidders are requested to take note of these amendments when preparing and submitting their bids.

NB: Other clauses, which are not mentioned in this addendum No1 remain unchanged as announced in initial tender.

Sincerely,

Dr. Loko Abraham

Chief Executive Officer 

N0Name Technical specification 
1Tetra Vertical Electrophoresis cells Vertical gel electrophoresis; includes casting stand with clamps; compatible with precast and hand cast gels; uniform electric field; leak-proof design
2Ultrasound sonicatorAdjustable frequency and power; probe-based or bath system; temperature control; suitable for cell lysis and homogenization; safety enclosure
3Eye bank Specular Microscope Features“Donor Enhance” (D+ only) for enhanced views of epithelium, endothelium, and stroma.TypeField of view: 1000 x 750 μmMax. analysis area 400 x 300 μm x 4 pointsCamera CMOS. Movin range of Stage X:16mm, Y:16mm, Z:16mmInput voltage AC100~240V, 50/60HzNjcn Weight: 7.5 kg (without computer). Data Interface: USB 2.0., HDMI Calibration: Includes a 20µm grid calibration disk. Operating Conditions: 10 to 40°C, 30 to 85% relative humidity, 70 to 106 kPa at  Compatibility: Adaptable to most commercially available cornea tissue storage . Chambers /vials